Objective: The purpose of this in vitro study was to determine the minimum depth of mineral trioxide aggregate (MTA; ProRoot; DENTSPLY/Tulsa Dental, Tulsa, Okla) required to maintain an apical seal following root resection. Study design. In 10 instrumented teeth, MTA was used to obturate the apical 6 mm of the root canal and was allowed to set for 48 hours. Leakage was determined by means of a fluid filtration method at a pressure of 20 cm H(2)O. Leakage was measured before root resection, and after 3, 4, 5, and 6 mm apical resections. Data were analyzed by means of a Kruskal-Wallis one-way analysis of variance with P <.05.
Results: Fluid leakage was shown to increase after each resection, but did not reach statistical significance (P <.05) until 4 mm of the apex had been removed.
Conclusion: The results indicate that root resection did not significantly affect the sealing ability of MTA when at least 3 mm of the MTA remained. Although there was a statistically significant difference in leakage following the 4 mm resection, it is unknown what the biological difference would be between the 3 mm and 4 mm resections.