Objective: We evaluated risk factors for mortality and stroke after mechanical mitral valve replacement between May 1977 and December 2001.
Methods: Early and late mortality and stroke were assessed. Potential predictors of mortality and stroke were entered into a Cox proportional hazards model. Actuarial survival and freedom from stroke were determined by a log-rank test.
Results: Mitral valve replacement was performed in 812 patients. Concomitant procedures included left atrial appendage closure in 493 (61%) patients, tricuspid annuloplasty-replacement in 348 (43%) patients, maze procedure in 185 (23%) patients, plication of the left atrium in 148 (18%) patients, and other procedures in 151 (19%) patients. Five-year actuarial survival was 91.1% +/- 2.3%. Freedom from stroke at 8 years was significantly better in patients with sinus rhythm versus atrial fibrillation (P <.001). Ninety-nine percent of patients with mitral valve replacement combined with a maze procedure were free from stroke, whereas only 89% of patients with mitral valve replacement alone were free from stroke at 8 years after surgical intervention. Seventy-two patients had late stroke; sixty-five patients (90%) were in atrial fibrillation, and 47 (65%) patients had the left atrial appendage closed. Multivariate analysis showed that late atrial fibrillation (odds ratio, 3.39; 95% confidence interval, 1.72-6.67; P =.0001) and omission of the maze procedure (odds ratio, 3.40; 95% confidence interval, 1.14-10.14; P =.003) were the significant risk factors for late stroke.
Conclusions: Persistent atrial fibrillation was the most significant risk factor for late stroke after mechanical mitral valve replacement. Restoration of sinus rhythm with a maze procedure nearly eliminated the risk of late stroke, whereas neither closure of the left atrial appendage nor therapeutic anticoagulation prevented this complication.