[A biliary fistula after T-tube removal in the transplant patient: its diagnosis by Tc-99m-HIDA]

Rev Esp Enferm Dig. 1992 Sep;82(3):165-8.
[Article in Spanish]

Abstract

The Tc-99m HIDA scan is a valuable study after liver transplantation, associated with other image techniques. We have used this technique as a reliable and objective diagnostic method for biliary fistula after removal of the T-tube in 5 liver transplantation patients with pain after T-tube removal. All five patients who developed fistula not only were diagnosed immediately but, furthermore, the surgical technique was indicated by the gammagraphic study. After this experience, we propose to remove the T-tube during the Tc-99 HIDA scan.

MeSH terms

  • Biliary Fistula / diagnostic imaging*
  • Biliary Fistula / etiology
  • Biliary Fistula / surgery
  • Drainage / adverse effects
  • Drainage / instrumentation*
  • Gamma Cameras
  • Humans
  • Imino Acids*
  • Liver Transplantation / diagnostic imaging*
  • Organotechnetium Compounds*
  • Postoperative Complications / diagnostic imaging*
  • Postoperative Complications / etiology
  • Postoperative Complications / surgery
  • Radionuclide Imaging
  • Technetium Tc 99m Lidofenin

Substances

  • Imino Acids
  • Organotechnetium Compounds
  • Technetium Tc 99m Lidofenin