Fracture load of CAD/CAM-generated slot-inlay FPDs

Int J Prosthodont. 2003 Nov-Dec;16(6):653-60.

Abstract

Purpose: This study investigated fracture load of computer-aided design/manufacturing (CAD/CAM)-generated slot-inlay fixed partial dentures (FPD) machined from ceramic and composite.

Materials and methods: Ninety slot-inlay FPDs were machined in groups of 15 specimens each using the same design on a Cerec 3 unit. Materials were assigned to groups: (1) Mk II feldspathic ceramic, (2) ProCAD glass-ceramic, (3) glass-ceramic 1, (4) glass-ceramic 2, (5) composite 1, and (6) composite 2. The slot-inlay FPDs were placed on models with two abutment teeth without cementation and loaded to fracture. For control, test bars (n = 15) were machined from each of the materials, and flexural strength was examined using three-point bending. Data were statistically analyzed using ANOVA and Scheffé tests.

Results: Fracture load of groups 4 (1,557 N, SD 236), 5 (1,048 N, SD 77), and 6 (1,512 N, SD 106) was significantly higher than that of groups 1 (652 N, SD 53) and 2 (773 N, SD 65). Flexural strength of group 4 (256 MPa, SD 20) was significantly higher than that of groups 1 (103 MPa, SD 6), 2 (127 MPa, SD 15), 3 (162 MPa, SD 32), 5 (178 MPa, SD 18), and 6 (170 MPa, SD 20).

Conclusion: Fracture loads of glass-ceramic 2 and composite 2 appear adequate for CAD/CAM slot-inlay FPDs.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aluminum Silicates / chemistry
  • Analysis of Variance
  • Ceramics / chemistry
  • Composite Resins / chemistry
  • Computer-Aided Design*
  • Dental Abutments
  • Dental Porcelain / chemistry
  • Dental Restoration Failure
  • Denture Design*
  • Denture, Partial, Fixed*
  • Glass / chemistry
  • Humans
  • Inlays*
  • Materials Testing
  • Pliability
  • Potassium Compounds / chemistry
  • Stress, Mechanical
  • Weight-Bearing

Substances

  • Aluminum Silicates
  • Composite Resins
  • Potassium Compounds
  • ProCAD Ceramic
  • Dental Porcelain
  • feldspar
  • Cerec