Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model

Radiology. 2004 Jun;231(3):697-701. doi: 10.1148/radiol.2313030132. Epub 2004 Apr 29.

Abstract

Purpose: To assess the role of contrast material-enhanced retrospectively electrocardiographically (ECG) gated multi-detector row computed tomography (CT) in the detection of acute myocardial infarction in a porcine model of total coronary occlusion.

Materials and methods: Seven Yorkshire farm pigs were studied with contrast-enhanced retrospectively ECG-gated multi-detector row CT 3 hours after total occlusion of the distal left anterior descending artery (n = 5) or the second diagonal branch (n = 2). Reformatted short-axis end-systolic and end-diastolic CT data sets were assessed for myocardial perfusion deficits, coronary occlusion, and abnormal myocardial wall motion. Perfusion deficits were compared with microsphere-determined blood flow and triphenyltetrazolium chloride (TTC)-stained tissue samples for infarct assessment by using Bland-Altman analysis and analysis of variance.

Results: Myocardial perfusion deficits, occlusion of the left anterior descending artery or second diagonal branch, and akinesis of the infarcted segment were identified in all five animals that completed the study. One animal died, and one data set had nondiagnostic image quality. The CT end-diastolic (mean, 16.1% +/- 4.8 [SD]; range, 8.6%-22.2%) and end-systolic (mean, 17.0% +/- 6.4; range, 8.7%-26.8%) volume of perfusion deficit was similar to that of infarcted tissue at TTC staining (mean, 13.6% +/- 6.0; range, 7.8%-30.9%). Infarcted myocardium at CT demonstrated a 76.1% reduction in microsphere-determined blood flow and a significant reduction of myocardial CT attenuation compared with normal myocardium (P <.01). Myocardial wall motion analysis demonstrated absence of systolic wall thickening in infarcted myocardium.

Conclusion: Multi-detector row CT with retrospective ECG gating permits the detection and further characterization of acute myocardial infarction in a porcine model of complete coronary occlusion.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Contrast Media*
  • Coronary Circulation
  • Electrocardiography
  • Female
  • Image Processing, Computer-Assisted
  • Male
  • Microspheres
  • Myocardial Contraction
  • Myocardial Infarction / diagnosis
  • Myocardial Infarction / diagnostic imaging*
  • Myocardial Infarction / pathology
  • Myocardial Infarction / physiopathology
  • Myocardium / pathology
  • Swine
  • Tomography, X-Ray Computed* / methods

Substances

  • Contrast Media