Imaging using Tc99m-tetrofosmin for the detection of the recurrence of brain tumour: a comparative study with Tc99m-glucoheptonate

J Postgrad Med. 2004 Apr-Jun;50(2):89-93.

Abstract

Background: In the past "blood-brain barrier" agents such as Tc99m-glucoheptonate were routinely used for the diagnosis of brain tumours. Of late, agents used for studying myocardial perfusion namely, Tc99m-tetrofosmin, Thallium-201, and Tc99m-sestamibi have replaced the "blood-brain barrier agents " when imaging is undertaken for the detection of the recurrence of brain tumours. However, the incremental diagnostic information provided by Tc99m-tetrofosmin when compared with a blood brain barrier agent in the diagnosis of recurrent brain tumour has not been evaluated till date.

Aims: The study was carried out to substantiate whether Tc99m-tetrofosmin provides any incremental diagnostic information not provided by the blood brain barrier agent Tc99m-glucoheptonate.

Material and methods: Brain SPECT scans were performed using Tc99m-tetrofosmin and Tc99m-glucoheptonate in 126 patients of recurrent brain tumour. Bio-distribution and uptake properties of both the tracers were analysed by measuring relative uptake of both the tracers in tumour compared to background (T/B ratio), nasopharynx (T/N ratio) and scalp (T/S ratio).

Statistical analysis: Descriptive statistics were calculated for each variable. Pearson's correlation coefficient was applied to see agreement of the continuous variables. Paired t test was used to evaluate the difference between two means.

Results: Uptake properties of both the tracers were analysed in 105 patients in whom both Tc99m-tetrofosmin and Tc99m-glucoheptonate showed concentration. The remaining 21 patients in whom the tumour mass did not show Tc99m-tetrofosmin concentration were excluded from the study. Mean T/B ratio, T/N ratio and T/S ratio was 5.83 + 2.09 and 5.99 + 2.26, 0.53 + 0.21 and 0.55 + 0.22 and 1.11 + 0.60 and 1.26 + 0.52 for Tc99m-tetrofosmin and Tc99m-glucoheptonate respectively. No statistically significant difference between T/B ratio and T/N ratio of Tc99m-tetrofosmin and Tc99m-glucoheptonate was found; p values were 0.25 and 0.83 respectively. However there was significant difference (P=0.006) between the T/S ratio of Tc99m-tetrofosmin and that of Tc99m-glucoheptonate.

Conclusion: Tc99m-tetrofosmin does not provide any incremental diagnostic information not provided by the blood brain barrier agent Tc99m-glucoheptonate.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Brain Neoplasms / diagnostic imaging*
  • Child
  • Child, Preschool
  • Female
  • Humans
  • Male
  • Middle Aged
  • Neoplasm Recurrence, Local / diagnostic imaging*
  • Organophosphorus Compounds*
  • Organotechnetium Compounds*
  • Radiopharmaceuticals*
  • Sugar Acids*
  • Tomography, Emission-Computed, Single-Photon

Substances

  • Organophosphorus Compounds
  • Organotechnetium Compounds
  • Radiopharmaceuticals
  • Sugar Acids
  • technetium tc-99m tetrofosmin
  • technetium Tc 99m gluceptate