Safety, pharmacokinetics, immunogenicity, and biodistribution of (186)Re-labeled humanized monoclonal antibody BIWA 4 (Bivatuzumab) in patients with early-stage breast cancer

Cancer Biother Radiopharm. 2004 Dec;19(6):720-9. doi: 10.1089/cbr.2004.19.720.

Abstract

The aim of this prospective study was to evaluate the safety, pharmacokinetics, immunogenicity, and biodistribution of (186)Re-labeled humanized anti-CD44v6 monoclonal antibody (MAb( BIWA 4 (Bivatuzumab( in 9 patients with early-stage breast cancer. Radioimmunoscintigraphy (RIS( was performed within 1, 24, and 72 hours after administration. BIWA 4 concentration in plasma (ELISA and radioactivity measurements( and the development of human antihuman antibody (HAHA( responses was determined. The biodistribution of (186)Re-BIWA 4 was determined by radioactivity measurements in tumor and normal tissue biopsies obtained during surgery 1 week after administration. Administration of (186)Re-BIWA 4 was well tolerated by all patients and no HAHA responses were observed. The mean t(1/2) in plasma of BIWA 4 (ELISA( was 81 hours (range, 67-97(, whereas the mean radioactivity t(1/2) tended to be longer, at 105 hours (range, 90-114(. RIS unmistakably showed the tumor in 3 patients. Less clear identifications were established in 3 additional patients. In 2 patients, the tumor was wrongly identified in the contralateral breast. Median tumor CD44v6 expression, as determined by immunohistochemistry, was 70% (range, 10-90%). Mean tumor uptake was 2.96% ID/kg (range, 0.92-6.27(, with no apparent correlation with either tumor CD44v6 expression, tumor-cell cellularity, or tumor diameter. Tumor-to-nontumor ratios were unfavorable for blood, bone marrow, mammary gland tissue, and skin.

Conclusions: The (186)Re-labeled humanized MAb BIWA 4 can safely be administered to patients with early-stage breast cancer. Tumorto- nontumor ratios were unfavorable, with no apparent correlation with CD44v6 expression, tumor-cell cellularity, or tumor diameter. BIWA 4, therefore, appears to have limitations as a vehicle for radioimmunotherapy in patients with breast cancer.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Antibodies, Monoclonal / immunology*
  • Antibodies, Monoclonal / pharmacokinetics*
  • Antibodies, Monoclonal, Humanized
  • Breast Neoplasms / diagnostic imaging
  • Breast Neoplasms / metabolism*
  • Carcinoma, Ductal, Breast / diagnostic imaging
  • Carcinoma, Ductal, Breast / metabolism*
  • Female
  • Glycoproteins / immunology*
  • Humans
  • Hyaluronan Receptors / immunology*
  • Middle Aged
  • Prospective Studies
  • Radioimmunodetection
  • Radioisotopes*
  • Rhenium*
  • Safety

Substances

  • Antibodies, Monoclonal
  • Antibodies, Monoclonal, Humanized
  • CD44v6 antigen
  • Glycoproteins
  • Hyaluronan Receptors
  • Radioisotopes
  • monoclonal antibody BIWA 4
  • Rhenium