[Prediction the octane number of gasoline by near infrared spectra analysis]

Guang Pu Xue Yu Guang Pu Fen Xi. 1999 Jun;19(3):314-7.
[Article in Chinese]

Abstract

The feasibility of predicting the octane number by the near infrared spectra analysis technique in the quantitative analysis was investigated. 12 calibration gasoline samples and 4 prediction samples were collected and their absorption spectra were measured with a high precision model Lambda 19 scanning spectrophotometer. Based on the multivariate statistic model, stagewise regression and partial least squares were selected. A model of the correlation behavior between the spectra and octane number was established and calibrated, and then the prediction of octane number is made. The prediction error is +/-1.0 octane number in the best analysis results.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Gasoline / analysis*
  • Octanes / chemistry*
  • Quality Control
  • Spectrophotometry, Infrared / methods*

Substances

  • Gasoline
  • Octanes
  • octane