Purpose: To evaluate the safety and efficacy of laser in situ keratomileusis (LASIK) to correct refractive error following cataract surgery.
Setting: The Eye Institute, Sydney, Australia.
Methods: This retrospective study reviewed 23 eyes (19 patients; 10 female, 9 male) treated with LASIK for refractive error following cataract surgery. The Summit Apex Plus and Ladarvision excimer laser and the SKBM microkeratome were used. The mean age was 63.5 years (range 50 to 88 years). The mean length of follow-up was 8.4 months (range 1 to 12 months) and mean interval between cataract surgery and LASIK was 12 months (range 2.5 to 46 months).
Results: The mean preoperative spherical equivalent refraction (SEQ) for myopic eyes was -3.08 +/- 0.84 diopters (D) (range -4.75 to -2.00 D) and for hyperopic eyes was +1.82 +/- 1.03 D (range +0.75 to +3.00 D). The mean improvement following LASIK surgery was greater for myopic than hyperopic eyes (myopic, 2.54 +/- 1.03 D versus hyperopic, 1.73 +/- 0.62 D; P=.033). The percentage of patients within +/-0.5 D of intended refraction post-LASIK surgery was 83.3% for myopic eyes and 90.9% for hyperopic eyes and all eyes were within +/-1.0 D of intended (P<.001). The percentage of eyes with uncorrected visual acuity of 20/40 or better in the myopic group improved from none preoperatively to 91.7% postoperatively (P<.001) and in the hyperopic group improved from 27.3% preoperatively to 90.9% postoperatively (P=.008). No eyes lost 2 or more lines of best corrected visual acuity.
Conclusion: Laser in situ keratomileusis appears to be effective in correcting refractive error following cataract surgery. Longer-term studies are required to determine refractive stability.