Objective: This study was undertaken to evaluate the effect of triiodothyronine replacement on the early postoperative course of neonates undergoing aortic arch reconstruction.
Methods: We performed a randomized, double-blind, placebo-controlled trial of triiodothyronine supplementation in neonates undergoing either a Norwood procedure or two-ventricle repair of interrupted aortic arch and ventricular septal defect. Patients were assigned to receive a continuous infusion of triiodothyronine (0.05 micro/kg/h) or placebo for 72 hours after cardiopulmonary bypass. Primary end points were a composite clinical outcome score and cardiac index at 48 postoperative hours.
Results: We enrolled 42 patients (triiodothyronine n = 22, placebo n = 20). Baseline characteristics were similar in the treatment groups. Study drug was discontinued prematurely because of hypertension (n = 1) and ectopic atrial tachycardia (n = 1), both cases in the triiodothyronine group. Free and total triiodothyronine levels were higher in the triiodothyronine group than in the placebo group at 24, 48, and 72 postoperative hours (P < .001). The median clinical outcome scores were 2.0 (range 0-4) with triiodothyronine and 2.0 (range 0-7) with placebo (P = .046). Compared with those in the placebo group, neonates assigned to triiodothyronine had shorter median time to negative fluid balance (2.0 vs 2.5 days, P = .027). Cardiac index values were 2.11 +/- 0.64 L/min x m2 with triiodothyronine and 2.05 +/- 0.72 L/min x m2 with placebo (P = .81). Heart rate and diastolic blood pressure were not influenced by triiodothyronine supplementation, but systolic blood pressure was higher in the triiodothyronine group (P < .001). No serious adverse events were attributed to triiodothyronine administration.
Conclusion: Triiodothyronine supplementation was safe and resulted in more rapid achievement of negative fluid balance after aortic arch reconstruction. Cardiac index at 48 hours was not significantly improved.