Treatment of ventricular assist device driveline infection with vacuum-assisted closure system

Ann Thorac Surg. 2005 Oct;80(4):1493-5. doi: 10.1016/j.athoracsur.2004.03.043.

Abstract

Deep driveline infection is a serious complication after left ventricular assist device implantation. Current treatment strategies are associated with significant morbidity related to healing or relocation of the driveline tract. We present a case of deep driveline infection successfully treated with a vacuum-assisted closure system as a potentially improved alternative therapy.

Publication types

  • Case Reports

MeSH terms

  • Abscess / etiology
  • Abscess / surgery
  • Adolescent
  • Anti-Bacterial Agents / therapeutic use
  • Cardiomyopathy, Dilated / complications
  • Cardiomyopathy, Dilated / therapy
  • Debridement / methods
  • Drainage / instrumentation
  • Drainage / methods
  • Heart-Assist Devices / adverse effects*
  • Humans
  • Male
  • Prosthesis-Related Infections / complications
  • Prosthesis-Related Infections / drug therapy
  • Prosthesis-Related Infections / surgery*
  • Pseudomonas Infections / complications
  • Pseudomonas Infections / drug therapy
  • Pseudomonas Infections / surgery*
  • Treatment Outcome
  • Vacuum