Objective: To assess the accuracy of the stereotactic implantation procedure of catheters containing I-125 seeds in brain tumours and investigate the effect of catheter deviations on the dose distribution in patients.
Methods: A randomised sample (n = 37) of all patients treated with I-125 seeds in our department between 6/1994 and 2/2002 was examined. Intraoperative X-ray images were used to measure deviations of implanted I-125 seed catheters from their planned positions and the influence on dose conformity, tumour surface dose and dose burden of surrounding healthy brain tissue was determined.
Results: The mean spatial target point deviation was 2.0 mm (maximum 4.1 mm, SD 0.9 mm) and in 54.1% of the cases, reduction of the planned dose was greater than 5%. Target point deviations less than 1.5 mm have only minor influence on surface dose and conformity. Results indicated that in 10.8% of the cases the realized dose distribution showed a 'slight deviation', according to the guideline criteria for external radiosurgery of the Radiation Therapy Oncology Group. In 89.2% of the patients the applied dose conformed to the target volume.
Conclusions: Stereotactically guided interstitial irradiation with I-125 seeds can be used to treat brain tumours and metastases with high conformity comparable to radiosurgery. The observed deviations of the stereotactically implanted I-125 seed catheters from their planned target points were smaller when compared to frameless procedures. In order to maintain the required spatial accuracy of 1.5 mm in interstitial therapy using I-125 seeds, it appears necessary to optimise stereotactic instruments further.