A sensitive method for the determination of hyoscine (scopolamine) in urine is described. After concentration and "clean-up" on C18 and CN solid phase extraction columns, hyoscine was quantified by high performance liquid chromatography with coulometric detection (oxidation at +0.9 V). The limit of detection was 5 ng per sample and the precision for 5 mL samples containing 2 ng/mL was 12.3%. The method was applied to urine samples collected from 12 volunteers wearing Scopoderm TTS patches. The mean excretion rate of unmetabolized hyoscine was 0.45 micrograms/h and 87% of the total hyoscine was present as conjugates. Apohyoscine (aposcopolamine) was identified as a urinary metabolite. The significance of this with regard to hyoscine assays is discussed.