Neurophysiological monitoring during thoracoabdominal aortic endovascular stent graft implantation

Eur J Cardiothorac Surg. 2006 Mar;29(3):392-6. doi: 10.1016/j.ejcts.2005.11.039. Epub 2006 Jan 24.

Abstract

Objective: The aim of this study was to evaluate the benefit of neurophysiological monitoring during thoracic and thoracoabdominal endovascular stent graft implantation.

Methods: The spinal cords of 21 patients undergoing endovascular stent graft implantation on the thoracic and thoracoabdominal aorta were monitored with transcranial motor-evoked potentials (tcMEP) and somatosensory-evoked potentials (SSEP). All patients underwent mild systemic hypothermia (34-35 degrees C), constant cerebrospinal fluid (CSF) pressure and vital parameter monitoring. If CSF pressure exceeded 15 mmHg, CSF-drainage was carried out.

Results: Three of the 21 patients (14%) exhibited short-term loss of tcMEP and SSEP after the deployment of the self-expanding endoprosthesis. We observed an intraoperative recovery of the evoked potentials in all cases. CSF-drainage was necessary in three of them. One patient, whose potentials were stable intraoperatively, developed paraparesis 3 weeks after the intervention.

Conclusions: Neurophysiological monitoring has proved to be an ideal monitoring method to detect spinal cord ischemia during thoracic and thoracoabdominal endovascular stent graft implantation. Due to the advantages of endovascular therapy (no aortic cross-clamping, continuous distal perfusion, and no reperfusion injury), changes in potentials were seldom observed.

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Anesthesia, General / methods
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortic Aneurysm, Thoracic / diagnostic imaging
  • Aortic Aneurysm, Thoracic / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects*
  • Blood Vessel Prosthesis Implantation / methods
  • Electric Stimulation / methods
  • Evoked Potentials, Motor
  • Evoked Potentials, Somatosensory
  • Female
  • Humans
  • Intraoperative Complications / diagnosis
  • Male
  • Middle Aged
  • Monitoring, Intraoperative / methods*
  • Postoperative Complications / prevention & control
  • Radiography
  • Spinal Cord / physiopathology
  • Spinal Cord Ischemia / diagnosis*
  • Spinal Cord Ischemia / etiology
  • Spinal Cord Ischemia / prevention & control
  • Stents
  • Treatment Outcome