Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography: comparison with cine magnetic resonance imaging

Eur Radiol. 2006 Jul;16(7):1424-33. doi: 10.1007/s00330-006-0169-6. Epub 2006 Mar 2.

Abstract

Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134+/-51 and 67+/-56 ml) were similar to those by MR (137+/-57 and 70+/-60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55+/-21 vs. 56+/-21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3+/-1.8 vs. 8.8+/-1.9 mm and 12.7+/-3.4 vs. 13.3+/-3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54+/-30 vs. 51+/-31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Artificial Intelligence
  • Coronary Artery Disease / complications
  • Coronary Artery Disease / diagnosis
  • Coronary Artery Disease / diagnostic imaging*
  • Electrocardiography / methods
  • Feasibility Studies
  • Female
  • Humans
  • Imaging, Three-Dimensional / methods
  • Information Storage and Retrieval / methods
  • Magnetic Resonance Imaging, Cine*
  • Male
  • Middle Aged
  • Radiographic Image Enhancement / methods
  • Radiographic Image Interpretation, Computer-Assisted / methods*
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Stroke Volume*
  • Tomography, X-Ray Computed / instrumentation
  • Tomography, X-Ray Computed / methods*
  • Transducers
  • Ventricular Dysfunction, Left / diagnosis
  • Ventricular Dysfunction, Left / diagnostic imaging*
  • Ventricular Dysfunction, Left / etiology