Fast CT-PRESS-based spiral chemical shift imaging at 3 Tesla

Magn Reson Med. 2006 May;55(5):974-8. doi: 10.1002/mrm.20853.

Abstract

A new sequence is presented that combines constant-time point-resolved spectroscopy (CT-PRESS) with fast spiral chemical shift imaging. It allows the acquisition of multivoxel spectra without line splitting with a minimum total measurement time of less than 5 min for a field of view of 24 cm and a nominal 1.5x1.5-cm2 in-plane resolution. Measurements were performed with 17 CS encoding steps in t1 (Deltat1=12.8 ms) and an average echo time of 151 ms, which was determined by simulating the CT-PRESS experiment for the spin systems of glutamate (Glu) and myo-inositol (mI). Signals from N-acetyl-aspartate, total creatine, choline-containing compounds (Cho), Glu, and mI were detected in a healthy volunteer with no or only minor baseline distortions within 14 min on a 3 T MR scanner.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms*
  • Biomarkers / analysis
  • Brain / metabolism*
  • Brain / pathology
  • Humans
  • Magnetic Resonance Imaging / methods*
  • Magnetic Resonance Spectroscopy / methods*