Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care

Comput Methods Programs Biomed. 2006 Jun;82(3):238-47. doi: 10.1016/j.cmpb.2006.03.004. Epub 2006 May 2.

Abstract

Hyperglycaemia is prevalent in critical illness and increases the risk of further complications and mortality, while tight control can reduce mortality up to 43%. Adaptive control methods are capable of highly accurate, targeted blood glucose regulation using limited numbers of manual measurements due to patient discomfort and labour intensity. Therefore, the option to obtain greater data density using emerging continuous glucose sensing devices is attractive. However, the few such systems currently available can have errors in excess of 20-30%. In contrast, typical bedside testing kits have errors of approximately 7-10%. Despite greater measurement frequency larger errors significantly impact the resulting glucose and patient specific parameter estimates, and thus the control actions determined creating an important safety and performance issue. This paper models the impact of the continuous glucose monitoring system (CGMS, Medtronic, Northridge, CA) on model-based parameter identification and glucose prediction. An integral-based fitting and filtering method is developed to reduce the effect of these errors. A noise model is developed based on CGMS data reported in the literature, and is slightly conservative with a mean Clarke Error Grid (CEG) correlation of R=0.81 (range: 0.68-0.88) as compared to a reported value of R=0.82 in a critical care study. Using 17 virtual patient profiles developed from retrospective clinical data, this noise model was used to test the methods developed. Monte-Carlo simulation for each patient resulted in an average absolute 1-h glucose prediction error of 6.20% (range: 4.97-8.06%) with an average standard deviation per patient of 5.22% (range: 3.26-8.55%). Note that all the methods and results are generalizable to similar applications outside of critical care, such as less acute wards and eventually ambulatory individuals. Clinically, the results show one possible computational method for managing the larger errors encountered in emerging continuous blood glucose sensors, thus enabling their more effective use in clinical glucose regulation studies.

MeSH terms

  • Adult
  • Aged
  • Blood Glucose / analysis*
  • Critical Care / methods*
  • Female
  • Humans
  • Hyperglycemia / blood
  • Hyperglycemia / prevention & control
  • Male
  • Middle Aged
  • Models, Statistical
  • Monitoring, Physiologic / methods*
  • Monte Carlo Method
  • Point-of-Care Systems*
  • Retrospective Studies
  • Software

Substances

  • Blood Glucose