[Indirect ELISA for the pyrethroids-permethrin residue detection]

Huan Jing Ke Xue. 2006 Feb;27(2):347-50.
[Article in Chinese]

Abstract

In order to detect the permethrin (Py) residue in environment samples, Ovalbumin(OVA)was used as protein carrier to couple with semi-antigen permethrin by active ester method. Indirect competitive ELISA (icELISA) was established. The most appropriate titration of coating antigen was 0.45 microg/mL and optimal dilution was 1/2 500 correspondingly. The standard curve of icELISA was also established and the curve indicated that the lowest detection limit was 0.l microg/mL, the curve had a favorable linear relation with the concentration range of 10 to approximately 800 microg/mL, recoveries of permethrin (>97%) were satisfactory.

Publication types

  • English Abstract
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Enzyme-Linked Immunosorbent Assay / methods
  • Insecticides / analysis*
  • Permethrin / analysis*
  • Pesticide Residues / analysis*
  • Pyrethrins / analysis*

Substances

  • Insecticides
  • Pesticide Residues
  • Pyrethrins
  • Permethrin