Coronary stenting can significantly reduce the restenosis and reocclusion rates after successful balloon angioplasty for chronic total occlusions (CTO). Nevertheless, recanalization of CTO remains among the worst predictors for in-stent restenosis and reocclusion. This multicenter, nonrandomized study assessed the safety and effectiveness of the CYPHER sirolimus-eluting stent in reducing angiographic in-stent late loss in totally occluded native coronary arteries. A total of 25 eligible patients were treated with the CYPHER sirolimus-eluting stent. Baseline clinical and angiographic data were collected and 6-month follow-up angiography and intravascular ultrasound (IVUS) were performed. Clinical follow-up was required at 30 days, 6, 12, 18, and 24 months. Study stent implantation was successful in all patients, with a mean stent length of 28.4 +/- 11 mm. Six-month angiographic outcomes showed that mean lumen diameter stenosis did not change (2.22 +/- 0.56 mm postprocedure; 2.26 +/- 0.60 mm at 6 months follow-up; P = NS). Similarly, mean percent diameter stenosis did not change significantly (15.7 +/- 8.6% postprocedure, 19.3 +/- 11% at follow-up; P = NS). The absolute late lumen loss was -0.03 +/- 0.28 mm with a 6-month in-stent restenosis rate of 0%. IVUS follow-up revealed in-stent obstruction volume of only 4.9 +/- 6.8%. Long-term clinical follow-up showed target lesion revascularization at 12 months was only 4%, with target vessel revascularization of only 12%. The CYPHER sirolimus-eluting stent was safe and effective in the treatment of CTO compared to historical data with bare metal stents.