Background: Weak signals for allergen-specific IgE are a problem in murine models for the study of allergies. It has been reported that the removal of IgG from murine sera enhances signal intensity. Very recently, buffer solutions designed to enhance signals in immunoassays have been developed and made commercially available.
Methods: Sera from mice immunized either with a recombinant form of one of the major mite allergens Der p 1, Der f 1 and Der f 2, or with ovalbumin adsorbed to alum were used for the assays. Total IgE was measured by a sandwich enzyme-linked immunosorbent assay (ELISA). Allergen-specific IgE was assayed using plates coated with the allergens after the removal of IgG from sera with protein G-coupled sepharose beads in wells of other plates or with the use of commercially available enhancer solutions without the removal of IgG. IgE binding was detected with horseradish peroxidase-conjugated anti-murine IgE monoclonal antibody as the secondary antibody.
Results: Significant levels of total IgE were produced after the immunizations. The in-well pretreatment of diluted sera (1/10 dilution) with protein G-coupled beads enhanced the signals for allergen-specific IgE. The use of the enhancer solutions for dilution of the sera and secondary antibody and prolonged incubation remarkably enhanced the signals at a more extensive dilution of sera (1/200 or less) without the removal of IgG.
Conclusions: An ELISA simply modified with the use of immunoreaction enhancer solutions has advantages in terms of signal intensity and ease of handling for the detection of allergen-specific murine IgE and would be useful for the study of allergies with murine models.