Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

Int J Radiat Oncol Biol Phys. 2006 Nov 15;66(4):1125-34. doi: 10.1016/j.ijrobp.2006.06.025.

Abstract

Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer.

Methods and materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test.

Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up "too deep" (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI > or =25 kg/m2 compared with patients of normal weight (47% vs. 28%, p = 0.068).

Conclusions: BMI > or =25 kg/m2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT-induced perfusion defects.

Publication types

  • Clinical Conference
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Adult
  • Age Distribution
  • Aged
  • Aged, 80 and over
  • Breast Neoplasms / epidemiology*
  • Breast Neoplasms / radiotherapy*
  • Comorbidity
  • Female
  • Humans
  • Medical Errors / statistics & numerical data*
  • Middle Aged
  • North Carolina / epidemiology
  • Prevalence
  • Radiation Injuries / epidemiology*
  • Radiotherapy, Conformal / statistics & numerical data*
  • Risk Assessment / methods*
  • Risk Factors
  • Sex Distribution
  • Stroke Volume
  • Ventricular Dysfunction, Left / epidemiology*