A high-performance liquid chromatographic method coupled with tandem mass spectrometry detection has been developed for the determination of propofol and its main glucuroconjugate metabolites (propofol-glucuronide (PG), 1-quinol-glucuronide (1-QG) and 4-quinol-glucuronide (4-QG) in human plasma. All compounds were extracted with a single solid phase extraction procedure using Max Oasis cartridges. Propofol and thymol (internal standard) were analyzed using a C8 reversed-phase column with a mobile phase consisting of methanol-water (75:25, v/v) containing 0.025% NH(4)OH. Chromatography of glucuroconjugate metabolites and phenyl-beta-d-glucuronide (internal standard) was performed using a hydrophilic interaction liquid chromatography (HILIC) and a mixture of acetonitrile/water/ammonium acetate buffer (100 mM, pH 5, 87/1/12, v/v/v). Both chromatographic separations were achieved in isocratic mode allowing a rapid analysis without re-equilibration of the phase. The method is specific and sensitive with a range of 10-1500 ng mL(-1) for propofol and 1-QG, 20-3000 ng mL(-1) for PG and 25-3750 ng mL(-1) for 4-QG. The regression curves were linear for all compounds. The method is accurate and precise with intra-assay and inter-assay precision <8% and bias < or =6% for all compounds. This assay has allowed the successful measurement of propofol and its main glucuroconjugate metabolites in human plasma from 24 patients undergoing anaesthesia for elective partial hepatectomy surgery.