Abstract
For anatomic and technical reasons, it is often difficult to achieve guiding-catheter stability in the segmental arteries during embolization of spinal vascular lesions. We have developed a segmental artery exchange technique using a thin-walled 4F nontapered catheter that is safe and achieves a stable guiding-catheter position. This catheter accommodates both the flow-guided and variable-stiffness microcatheters, allowing selective catheterization and treatment of spinal vascular lesions.
MeSH terms
-
Angiography, Digital Subtraction
-
Arteriovenous Malformations / diagnostic imaging
-
Arteriovenous Malformations / pathology
-
Arteriovenous Malformations / therapy*
-
Catheterization / instrumentation*
-
Central Nervous System Vascular Malformations / diagnostic imaging
-
Central Nervous System Vascular Malformations / pathology
-
Central Nervous System Vascular Malformations / therapy
-
Embolization, Therapeutic / instrumentation*
-
Embolization, Therapeutic / methods*
-
Humans
-
Spinal Cord / blood supply*