Diagnosis of focal liver masses on ultrasonography: comparison of unenhanced and contrast-enhanced scans

J Ultrasound Med. 2007 Jun;26(6):775-87; quiz 788-90. doi: 10.7863/jum.2007.26.6.775.

Abstract

Objective: The purpose of this study was to compare the diagnostic accuracy, confidence level, and recommended management of focal liver masses after contrast-enhanced ultrasonography (CEUS) compared with unenhanced ultrasonography alone.

Methods: One hundred sixty-seven patients were referred for CEUS to characterize a focal liver mass. A 2-person blind read determined benignancy or malignancy, comparative diagnosis, and accuracy on both ultrasonography and CEUS. Results were compared with the final diagnoses.

Results: The 2 readers could not determine benignancy or malignancy in 77 (46.1%) and 46 (27.5%) of 167 unenhanced scans compared with 2 (1.2%) and 1 (0.6%) of 167 CEUS scans. The confidence level increased from 0 responses in the 2 highest grades (4 and 5) on the unenhanced scans to 135 (81.8%) and 132 (79.5%) of 167 at level 5 for CEUS. Regarding the diagnosis, the confidence level was lowest (grade 1) on the unenhanced scans in 128 (82.1%) and 79 (65.3%) of 167 for the 2 readers and improved to the highest (grade 5) in 110 (65.9%) and 113 (68.1%) of 167. Regarding diagnostic accuracy, the unenhanced scans agreed with the correct diagnosis in 85 (50.9%) and 63 (37.7%) of 167, and CEUS agreed with the correct diagnosis in 133 (79.6%) and 142 (85%) of 167 for readers 1 and 2, respectively. Recommendations for further imaging decreased from 166 (99.4%) and 147 (88%) of 167 on the unenhanced scans to 30 (18%) and 5 (3%) of 167 on CEUS for readers 1 and 2.

Conclusions: Contrast-enhanced ultrasonography improves the accuracy and confidence of diagnosis of focal liver lesions and reduces recommendations for further investigations.

Publication types

  • Comparative Study
  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Contrast Media
  • Female
  • Fluorocarbons*
  • Humans
  • Image Enhancement / methods*
  • Liver Neoplasms / diagnostic imaging*
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Ultrasonography

Substances

  • Contrast Media
  • Fluorocarbons
  • perflutren