In vivo 19F magnetic resonance spectroscopy and chemical shift imaging of tri-fluoro-nitroimidazole as a potential hypoxia reporter in solid tumors

Clin Cancer Res. 2007 Jun 15;13(12):3738-47. doi: 10.1158/1078-0432.CCR-06-1563.

Abstract

Purpose: 2-Nitro-alpha-[(2,2,2-trifluoroethoxy)methyl]-imidazole-1-ethanol (TF-MISO) was investigated as a potential noninvasive marker of tissue oxygen levels in tumors using (19)F magnetic resonance spectroscopy (MRS) and (19)F chemical shift imaging.

Experimental designs: In vitro data were obtained using high-performance liquid chromatography on tumor cells incubated under varying oxygen conditions to determine the oxygen-binding characteristics. In vivo data were obtained using a well-characterized hypoxic murine breast tumor (MCa), in addition to studies on a rat prostate tumor model (R3327-AT) implanted in nude mice. Detection of intratumor (19)F signal from TF-MISO was done using MRS for up to 10 h following a 75 mg/kg i.v. injection. Localized distribution of the compound in the implanted MCa tumor has been imaged using slice-selective two-dimensional chemical shift imaging 6 h after injection.

Results: The in vitro results showed that TF-MISO preferentially accumulates in cells incubated under anoxic conditions. The in vivo (19)F MR spectral features (line width and chemical shift) were recorded as a function of time after injection, and the results indicate that the fluorine atoms are indeed sensitive to changes in the local environment while still providing a detectable MR signal. Ex vivo spectra were collected and established the visibility of the (19)F signal under conditions of maximum hypoxia. Late time point (>6 h) tumor tissue concentrations, as obtained from (19)F MRS, suggest that TF-MISO is reduced and retained in hypoxic tumor. The feasibility of obtaining TF-MISO tumor distribution maps in a reasonable time frame was established.

Conclusions: Based on the results presented herein, it is suggested that TF-MISO has the potential to be a valid magnetic resonance hypoxia imaging reporter for both preclinical hypoxia studies and hypoxia-directed clinical therapy.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Animals
  • Cell Hypoxia*
  • Chromatography, High Pressure Liquid
  • Fluorine Radioisotopes
  • Magnetic Resonance Imaging*
  • Magnetic Resonance Spectroscopy*
  • Male
  • Mice
  • Misonidazole / analogs & derivatives*
  • Misonidazole / pharmacokinetics
  • Neoplasms, Experimental / metabolism
  • Neoplasms, Experimental / pathology*

Substances

  • Fluorine Radioisotopes
  • 1-(2-nitro-1-imidazoyl)-3-(2,2,2-trifluoroethoxy)-2-propanol
  • Misonidazole