Background: We recently developed and validated limited sampling models (LSMs) for cyclosporine monitoring after orthotopic liver transplantation based on individualized population pharmacokinetic models with Bayesian modelling. Aim To evaluate LSM in practice, and to seek optimal balance between benefit and discomfort.
Methods: In 30 stable patients, more than 6 months after orthotopic liver transplantation, previously switched from trough- to 2 h post-dose (C2)-monitoring, we switched to 3-monthly LSM 0,1,2,3 h-monitoring. During 18 months we evaluated dose, creatinine clearance, calculated area under the curve, intra-patient pharmacokinetic variability and ability to assess systemic exposure by several previously validated LSMs.
Results: Within patients, there was variability of cyclosporine-area under the curve with the same dose (CV of 15%). Compared to C2-monitoring, there was no significant difference in dose (P = 0.237), creatinine clearance (P = 0.071) and number of rejections. Some models showed excellent correlation and precision with LSM 0,1,2,3 h comparing area under the curves (0,2 h: r(2) = 0.88; 0,1,3 h: r(2) = 0.91; 0,2,3 h: r(2) = 0.92, all P < 0.001) with no difference in advised dose.
Conclusions: The limited sampling model, with only trough- and 2-h sampling, yields excellent accuracy and assesses systemic exposure much better than C2 with less bias and greater precision. Considering the calculated intra-patient variability, more precision is redundant, so LSM 0,2 h seems the optimal way of cyclosporine-monitoring.