Poloidal beta and internal inductance measurement on HT-7 superconducting tokamak

Rev Sci Instrum. 2007 Sep;78(9):093501. doi: 10.1063/1.2779213.

Abstract

Poloidal beta beta(theta) and internal inductance l(i) measurements are very important for tokamak operation. Much more plasma parameters can be inferred from the two parameters, such as the plasma energy confinement time, the plasma toroidal current profile, and magnetohydrodynamics instability. Using diamagnetic and compensation loop, combining with poloidal magnetic probe array signals, poloidal beta beta(theta) and internal inductance l(i) are measured. In this article, the measurement system and arithmetic are introduced. Different experimental results are given in different plasma discharges on HT-7 superconducting tokamak.