We present a case of serial regression of aneurysm of coronary artery complicating paclitaxel-eluting Taxus stent implantation in the mid anterior descending artery evaluated by intravascular ultrasound in a 55-year-old woman.

Publication types

  • Case Reports
  • Letter

MeSH terms

  • Antineoplastic Agents, Phytogenic / pharmacology*
  • Blood Vessel Prosthesis Implantation / adverse effects*
  • Blood Vessel Prosthesis Implantation / instrumentation
  • Coated Materials, Biocompatible / adverse effects*
  • Coronary Aneurysm / diagnostic imaging*
  • Coronary Aneurysm / etiology
  • Female
  • Humans
  • Middle Aged
  • Myocardial Infarction / surgery
  • Paclitaxel / pharmacology*
  • Stents / adverse effects*
  • Ultrasonography, Interventional / methods*

Substances

  • Antineoplastic Agents, Phytogenic
  • Coated Materials, Biocompatible