Total cavopulmonary connection: a modified technique without prosthetic material

J Card Surg. 1991 Jun;6(2):294-7; discussion 297-8. doi: 10.1111/j.1540-8191.1991.tb00312.x.

Abstract

An alternative method to create an intraatrial, cavocaval channel without using any prosthetic material in total cavopulmonary connection is described. This new technique avoids possible thrombotic complication, limitation of heart growth by intraatrial prosthetic material, and reduction in secretion of antinaturetic peptide.

Publication types

  • Case Reports

MeSH terms

  • Anastomosis, Surgical / methods
  • Cardiopulmonary Bypass
  • Child, Preschool
  • Female
  • Heart Atria / surgery
  • Heart Septal Defects, Ventricular / surgery
  • Humans
  • Pulmonary Artery / surgery*
  • Transposition of Great Vessels / surgery
  • Vena Cava, Superior / surgery*