Quantitative assessment of synovial vascularity using contrast-enhanced power Doppler ultrasonography: correlation with histologic findings and mr imaging findings in arthritic rabbit knee model

Korean J Radiol. 2008 Jan-Feb;9(1):45-53. doi: 10.3348/kjr.2008.9.1.45.

Abstract

Objective: To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings.

Materials and methods: Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment.

Results: The mean area of color pixels in PD US changed from 4.37 to 16.42 mm(2) in the arthritic knee after enhancement (p < 0.05), whereas it changed from 0.77 to 2.31 mm(2) in the control knee (p < 0.05). Arthritic knees had greater power Doppler signal than control knees both before and after contrast administration (p < 0.05). The average MVD was 88 in arthritic knees and 46 in control knees. MVDs correlated with color pixel areas of contrast-enhanced power Doppler imaging in arthritic knees. In MR grading of arthritic knees, five were grade 2 and eight were grade 3. MVD and PD US revealed no significant difference between grade 2 and 3 arthritic knees (p > 0.05).

Conclusion: Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Contrast Media
  • Gadolinium DTPA
  • Image Processing, Computer-Assisted
  • Immunohistochemistry
  • Magnetic Resonance Imaging
  • Osteoarthritis, Knee / diagnostic imaging*
  • Osteoarthritis, Knee / pathology
  • Polysaccharides
  • Rabbits
  • Statistics, Nonparametric
  • Synovial Membrane / blood supply*
  • Synovial Membrane / diagnostic imaging
  • Synovial Membrane / pathology
  • Ultrasonography, Doppler*

Substances

  • Contrast Media
  • Polysaccharides
  • SHU 508
  • Gadolinium DTPA