Modified protocols of two rapid tests were compared with a less sensitive (LS) (detuned) enzyme immunoassay (EIA) for their abilities to distinguish recent human immunodeficiency virus (HIV) seroconversion from long-term infections. The results for samples from 100 HIV-positive patient that had previously been tested by the Vironostika LS EIA had a 97% concordance with the results of the Determine HIV 1/2 assay and 93% concordance with those of the OraQuick HIV 1/2 assay.