Objective: To evaluate anti-HEV diagnostic kits by experimental infecting rhesus monkeys with HEV.
Methods: Eight rhesus monkeys were infected with genotype 1 and 4 HEV separately. The alanine aminotransferase (ALT) level of all monkeys were detected before and after the process of infection. HEV RNA in stool specimens was tested by reverse transcriptase-polymerase chain reaction (RT-PCR) assay. Anti-HEV IgG in serum was detected by GL-IgG and WT-IgG.
Results: HEV RNA presented in the stool of all the 8 monkeys after infection. The ALT level of 1 monkey infected with genotype 1 HEV and 2 monkeys infected with genotype 4 HEV appeared abnormally after infection. Tested by GL-IgG, 2 of the 4 monkeys infected with genotype 1 HEV and 1 of 4 monkeys infected with genotype 4 HEV seroconverted to anti-HEV IgG. However, when tested by WT-IgG, all the infected monkeys seroconverted to anti-HEV IgG. The anti-HEV IgG tested by WT-IgG was positive during the whole observation period,and the anti-HEV IgG measured by GL-IgG only remained 12 weeks after infection. Detected by GL-IgG and WT-IgG, seropositive conversion of the anti-HEV IgG happened almost at the same time.
Conclusion: Both GL-IgG and WT-IgG could detect the anti-HEV IgG of experimentally infected rhesus monkeys but the WT-IgG had a higher sensitivity for detection of anti-HEV IgG than