Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience

Endoscopy. 2009 May;41(5):445-8. doi: 10.1055/s-0029-1214643. Epub 2009 May 5.

Abstract

Background and study aims: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is now performed routinely in many advanced endoscopy centers and has enhanced the ability to diagnose pancreatic masses. However, there is uncertainty about which needle size is optimal for EUS-FNA of pancreatic masses. We aimed to evaluate the performance of the 22-gauge and 25-gauge needles in obtaining cytologic diagnosis of pancreatic masses.

Methods: All cases that were referred for EUS-FNA for pancreatic masses between February 2001 and June 2007 were reviewed, and patients who underwent EUS-FNA using the 22-gauge and 25-gauge needle system were identified. In patients who underwent surgery, operative histopathological findings were compared with the cytopathological findings from EUS-FNA.

Results: A total of 842 patients with pancreatic masses detected on computed tomography (CT) and/or magnetic resonance imaging (MRI) and confirmed by EUS underwent EUS-FNA with the 22-gauge needle (n = 540) or the 25-gauge needle (n = 302). Results of EUS-FNA cytology findings were compared with the gold standard of surgical histopathological findings or long-term clinical follow-up. The sensitivity, specificity, PPV, and NPV of FNA were respectively 84%, 100%, 100%, and 73% [corrected] for the 22-gauge needle compared with 92%, 97%, 98%, and 87%, [corrected] respectively for the 25-gauge needle. No complications were noted in the 25-gauge needle group, compared with pancreatitis in 2% of the 22-gauge needle group.

Conclusions: This retrospective comparative study shows that EUS-FNA with a 25-gauge needle system is a safe and reliable method for tissue sampling in pancreatic masses. The system is more sensitive and has a slightly [corrected] higher NPV than the standard 22-gauge needle. Our study suggests that perhaps the smaller caliber FNA needle causes less trauma during EUS-FNA and hence less complications. Further studies including randomized trials are needed.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Fine-Needle / adverse effects
  • Biopsy, Fine-Needle / instrumentation*
  • Diagnosis, Differential
  • Endosonography / instrumentation*
  • Equipment Design
  • Female
  • Humans
  • Male
  • Middle Aged
  • Needles
  • Pancreas / pathology
  • Pancreatic Neoplasms / pathology*
  • Pancreatitis / etiology
  • Retrospective Studies
  • Sensitivity and Specificity
  • Ultrasonography, Interventional / instrumentation*
  • Young Adult