Mesh fixation with autologous platelet-rich fibrin sealant in inguinal hernia repair

Eur Surg Res. 2009;43(3):306-9. doi: 10.1159/000233526. Epub 2009 Aug 13.

Abstract

Background: Chronic pain is the main complication following inguinal hernia repair. A possible explanatory factor is the suture fixation of the mesh. Glue fixation might overcome this problem. Albeit at a very low frequency, human and bovine components of fibrin sealants currently available could contain blood-borne pathogens. Autologous platelet-rich fibrin sealant (P-RFS) eliminates this risk and has additional advantages such as hemostatic and antibacterial effects. Therefore, its feasibility was assessed in inguinal hernia repair, with a focus on pain.

Methods: In 22 patients with primary inguinal hernia, the mesh was fixated with P-RFS. Data included operative variables, complications, pain scores and neurological examinations. Long-term follow-up was 22.2 months (SD 2.2) postoperatively.

Results: After 2 weeks, visual analogue scale and disability pain scores were lower than they were preoperatively. Complications at 3 months were 1 recurrence, 1 chronic pain and 6 sensory disturbances. At the last clinical evaluation, the recurrence was planned for repair due to discomfort. No chronic pain, sensory disorders or discomfort was reported at long-term follow-up.

Conclusion: Mesh fixation with autologous P-RFS is feasible. If there is a preference for autologous material, P-RFS is indicated. If glue fixation becomes standard, further randomized studies are warranted for this alternative.

Publication types

  • Clinical Trial

MeSH terms

  • Activities of Daily Living
  • Aged
  • Blood Transfusion, Autologous
  • Fibrin Tissue Adhesive / therapeutic use*
  • Hernia, Inguinal / surgery*
  • Humans
  • Male
  • Middle Aged
  • Pain, Postoperative / prevention & control*
  • Platelet Transfusion
  • Surgical Mesh*
  • Tissue Adhesives / therapeutic use*

Substances

  • Fibrin Tissue Adhesive
  • Tissue Adhesives