Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation

Rev Bras Cir Cardiovasc. 2009 Apr-Jun;24(2):233-8. doi: 10.1590/s0102-76382009000200021.

Abstract

Objective: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB.

Methods: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU.

Results: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation.

Conclusion: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning curve require further discussion.

Publication types

  • Case Reports

MeSH terms

  • Aged, 80 and over
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / therapy*
  • Bioprosthesis*
  • Cardiopulmonary Bypass
  • Catheterization / instrumentation*
  • Fatal Outcome
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Middle Aged
  • Prosthesis Design
  • Prosthesis Failure
  • Reoperation
  • Risk Assessment