Purpose: To investigate the possibility of reducing radiation dose exposure while maintaining image quality using multidetector computed tomography angiography (MDCTA) with high-concentration contrast media in patients undergoing follow-up after endovascular aortic repair (EVAR) to treat abdominal aortic aneurysm.
Materials and methods: In this prospective, single center, intra-individual study, patients underwent two consecutive MDCTA scans 6 months apart, one with a standard acquisition protocol (130 mAs/120 kV) and 120 mL of iomeprol 300, and one using a low dose protocol (100 mAs/80 kV) and 90 mL of iomeprol 400. Images acquired during the arterial phase of contrast enhancement were evaluated both qualitatively and quantitatively for image noise and intraluminal contrast enhancement.
Results: Thirty adult patients were prospectively enrolled. Statistically significantly higher attenuation values were measured in the low-dose acquisition protocol compared to the standard protocol, from the suprarenal abdominal aorta to the common femoral artery (p<0.0001; all vascular segments). Qualitatively, image quality was judged significantly (p=0.0002) better with the standard protocol than with the low-dose protocol. However, no significant differences were found between the two protocols in terms of contrast-to-noise ratio (CNR) (13.63±6.97 vs. 11.48±8.13; p=0.1058). An overall dose reduction of up to 74% was observed for the low-dose protocol compared with the standard protocol.
Conclusion: In repeat follow-up examinations of patients undergoing EVAR for abdominal aortic aneurysm, a low-dose radiation exposure acquisition protocol provides substantially reduced radiation exposure while maintaining a constant CNR and good image quality.
Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.