Efficient temperature compensation strategies for guided wave structural health monitoring

Ultrasonics. 2010 Apr;50(4-5):517-28. doi: 10.1016/j.ultras.2009.11.002. Epub 2009 Nov 26.

Abstract

The application of temperature compensation strategies is important when using a guided wave structural health monitoring system. It has been shown by different authors that the influence of changing environmental and operational conditions, especially temperature, limits performance. This paper quantitatively describes two different methods to compensate for the temperature effect, namely optimal baseline selection (OBS) and baseline signal stretch (BSS). The effect of temperature separation between baseline time-traces in OBS and the parameters used in the BSS method are investigated. A combined strategy that uses both OBS and BSS is considered. Theoretical results are compared, using data from two independent long-term experiments, which use predominantly A(0) mode and S(0) mode data respectively. These confirm that the performance of OBS and BSS quantitatively agrees with predictions and also demonstrate that the combination of OBS and BSS is a robust practical solution to temperature compensation.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Environmental Exposure
  • Humans
  • Mathematics
  • Monitoring, Physiologic / methods*
  • Temperature*