Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test

J Clin Microbiol. 2010 Mar;48(3):969-71. doi: 10.1128/JCM.01394-09. Epub 2009 Dec 30.

Abstract

No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

Publication types

  • Comparative Study
  • Evaluation Study
  • Multicenter Study

MeSH terms

  • HIV Infections / diagnosis*
  • HIV Infections / virology
  • HIV-1 / genetics
  • HIV-1 / isolation & purification*
  • Humans
  • Molecular Diagnostic Techniques / methods*
  • Sensitivity and Specificity