Contrast material for abdominal dynamic contrast-enhanced 3D MR angiography with parallel imaging: intraindividual equimolar comparison of a macrocyclic 1.0 M gadolinium chelate and a linear ionic 0.5 M gadolinium chelate

AJR Am J Roentgenol. 2010 Mar;194(3):821-9. doi: 10.2214/AJR.09.3306.

Abstract

Objective: The purpose of this study was to compare a macrocyclic 1.0 M contrast agent with a linear ionic 0.5 M contrast agent at equimolar dosage in regard to image quality and number of vessel segments visualized at abdominal dynamic contrast-enhanced 3D MR angiography.

Subjects and methods: In an intraindividual comparative study, 15 patients (six women, nine men; mean age, 53 +/- 12.1 years; range, 25-72 years) underwent 32 1.5-T whole-body contrast-enhanced 3D MR angiographic examinations performed with parallel imaging technique. At random and in separate sessions, each patient was examined after IV injection of 0.1 mmol/kg body weight 1.0 M macrocyclic gadobutrol and 0.5 M linear ionic gadopentetate dimeglumine. Three-dimensional data sets were acquired in the arterial, portal venous, and venous phases with identical imaging protocols. Quantitative analysis included contrast measurements of vessels compared with adjacent background tissue (Student's t test). Qualitative analysis was performed independently by two radiologists with regard to visualization of arterial and venous vessel segments and overall image quality (Wilcoxon's test).

Results: Visualization of individual vessel segments was rated significantly better after administration of 1.0 M macrocyclic gadobutrol compared with 0.5 M linear ionic gadopentetate dimeglumine (p < 0.001). Overall image quality was superior with 1.0 M macrocyclic gadobutrol, but the difference was not significant. Vessel-to-background contrast after injection of 1.0 M macrocyclic gadobutrol was significantly higher (arterial phase, 0.90, p = 0.02; portal venous phase, 0.78, p = 0.0002; venous phase, 0.74, p = 0.0002) compared with 0.5 M linear ionic gadopentetate dimeglumine (arterial phase, 0.89; portal venous phase, 0.73; venous phase, 0.67).

Conclusion: At abdominal contrast-enhanced 3D MR angiography, depiction of small abdominal vessels was significantly better and vessel-to-tissue contrast significantly higher with 1.0 M macrocyclic gadobutrol than with an equimolar dose of 0.5 M linear ionic gadopentetate dimeglumine.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Contrast Media / administration & dosage*
  • Female
  • Gadolinium DTPA / administration & dosage*
  • Humans
  • Image Interpretation, Computer-Assisted
  • Imaging, Three-Dimensional*
  • Kidney / blood supply*
  • Liver / blood supply*
  • Magnetic Resonance Angiography / methods*
  • Male
  • Middle Aged
  • Organometallic Compounds / administration & dosage*
  • Prospective Studies
  • Statistics, Nonparametric
  • Whole Body Imaging

Substances

  • Contrast Media
  • Organometallic Compounds
  • gadobutrol
  • Gadolinium DTPA