Performance of EUS-FNA for mediastinal lymphadenopathy: impact on patient management and costs in low-volume EUS centers

Surg Endosc. 2010 Sep;24(9):2260-7. doi: 10.1007/s00464-010-0946-9. Epub 2010 Feb 23.

Abstract

Background: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of mediastinal lymphadenopathy has been shown to be a valuable diagnostic tool in high-volume EUS centers (≥ 50 mediastinal EUS-FNA/endoscopist/year). Our goal was to assess the diagnostic accuracy of EUS-FNA and its impact on clinical management and costs in low-volume EUS centers (<50 mediastinal EUS-FNA/endoscopist/year).

Methods: Consecutive patients referred to two Dutch endoscopy centers in the period 2002-2008 for EUS-FNA of mediastinal lymphadenopathy were reviewed. The gold standard for a cytological diagnosis was histological confirmation or clinical follow-up of more than 6 months with repeat imaging. The impact of EUS-FNA on clinical management was subdivided into a positive impact by providing (1) adequate cytology that influenced the decision to perform surgery or (2) a diagnosis of a benign inflammatory disorder, and a negative impact which was subdivided into (1) false-negative or inconclusive cytology or (2) an adequate cytological diagnosis that did not influence patient management. Costs of an alternative diagnostic work-up without EUS-FNA, as established by an expert panel, were compared to costs of the actual work-up.

Results: In total, 213 patients (71% male, median age= 61 years, range = 23-88 years) underwent EUS-FNA. Sensitivity, specificity, and negative and positive predictive values were 89%, 100%, 80%, and 100%, respectively. EUS-FNA had a positive impact on clinical management in 84% of cases by either influencing the decision to perform surgery (49%) or excluding malignant lymphadenopathy (35%), and a negative impact in 7% of cases because of inadequate (3%) or false-negative (4%) cytology. In 9% of cases, EUS-FNA was performed without an established indication. Two nonfatal perforations occurred (0.9%). Total cost reduction was €100,593, with a mean cost reduction of €472 (SD = €607) per patient.

Conclusions: Mediastinal EUS-FNA can be performed in low-volume EUS centers without compromising diagnostic accuracy. Moreover, EUS-FNA plays an important role in the management of patients with mediastinal lymphadenopathy and reduces total diagnostic costs.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Biopsy, Fine-Needle / economics
  • Biopsy, Fine-Needle / methods*
  • Chi-Square Distribution
  • Endosonography* / economics
  • Female
  • Humans
  • Lymphatic Diseases / diagnostic imaging
  • Lymphatic Diseases / pathology*
  • Male
  • Mediastinal Diseases / diagnostic imaging
  • Mediastinal Diseases / pathology*
  • Middle Aged
  • Netherlands
  • Predictive Value of Tests
  • Sensitivity and Specificity
  • Ultrasonography, Interventional* / economics