Technetium-99m-L,L-ethylenedicysteine is more effective than technetium-99m diethylenetriamine penta-acetic acid for excluding obstruction in patients with pyelocalicinal dilation

Urology. 2010 Aug;76(2):283-8. doi: 10.1016/j.urology.2009.12.032. Epub 2010 Mar 5.

Abstract

Objective: To evaluate the utility of diuretic dynamic renal scintigraphy (DDRS) with technetium-99m-L,L-ethylenedicysteine ((99m)Tc-EC) in patients with indeterminate or possible false-positive results for urinary obstruction by technetium-99m diethylenetriamine penta-acetic acid ((99m)Tc-DTPA) DDRS.

Methods: A total of 92 patients (63 male; mean age, 16.6 +/- 21.25 years) were studied, with a total of 103 kidneys presenting indeterminate (20/103) or possible false-positive results for obstruction attributable to reduced renal function or severe kidney dilation (83/103) by (99m)Tc-DTPA DDRS (<60% of radiopharmaceutical excreted in 20 minutes-half-time clearance [T(1/2)] >15 minutes). Patients were reimaged after intravenous injection of (99m)Tc-EC, with dynamic images before and after furosemide administration using the same acquisition parameters applied in the previous (99m)Tc-DTPA study. Time interval between (99m)Tc-DTPA and (99m)Tc-EC renograms was 2-64 days. The percentage of excreted material 20 minutes after furosemide was calculated using both radiopharmaceuticals, and were statistically compared using the paired samples t test.

Results: The excretion after furosemide injection was 25.3% +/- 18.2% for (99m)Tc-DTPA and 41.2% +/- 26.1% for (99m)Tc-EC, with a statistically significant difference between both radiopharmaceuticals (P <.0001). Using (99m)Tc-EC obstruction was excluded in 36 of 103 kidneys, which excreted >60%. A total of 10 of 83 kidneys (12.0%) with an obstructive pattern by (99m)Tc-DTPA study turned out to be indeterminate by (99m)Tc-EC DDRS. There was an agreement between (99m)Tc-EC and (99m)Tc-DTPA studies in 54 of 83 kidneys with obstructive (65.1%) and in 3 of 20 (15.0%) with indeterminate patterns.

Conclusions: (99m)Tc-EC was more effective than (99m)Tc-DTPA for excluding obstruction, presenting less false-positive and indeterminate results. (99m)Tc-EC can substitute (99m)Tc-DTPA to evaluate patients with urinary tract dilation.

Publication types

  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Child
  • Child, Preschool
  • Cysteine / analogs & derivatives*
  • Dilatation, Pathologic
  • False Positive Reactions
  • Female
  • Humans
  • Infant
  • Kidney Pelvis*
  • Male
  • Middle Aged
  • Organotechnetium Compounds*
  • Radionuclide Imaging
  • Radiopharmaceuticals*
  • Technetium Tc 99m Pentetate*
  • Ureteral Obstruction / diagnostic imaging*
  • Young Adult

Substances

  • Organotechnetium Compounds
  • Radiopharmaceuticals
  • technetium Tc 99m-ethylenedicysteine
  • Cysteine
  • Technetium Tc 99m Pentetate