Can preoperative diffusion-weighted MRI predict postoperative hepatic insufficiency after curative resection of HBV-related hepatocellular carcinoma? A pilot study

Magn Reson Imaging. 2010 Jul;28(6):802-11. doi: 10.1016/j.mri.2010.03.018. Epub 2010 Apr 15.

Abstract

Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis in patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC). Twenty-six patients with HBV-related HCC who received preoperative DW-MRI on a 3-T MRI system were enrolled between July and December 2008. ADC values were measured twice by two observers. Three "b values" were used: 50, 400 and 800 s/mm(2). Postoperative hepatic insufficiency was defined as persistent hyperbilirubinemia (total bilirubin level >5 mg/dl for more than 5 days after surgery) or postoperative death without other causes. The mean age (21 men and 5 women) was 51.4 years. Three patients experienced postoperative hepatic insufficiency. liver stiffness measurement predicted postoperative hepatic insufficiency, advanced fibrosis (F3-4), and cirrhosis significantly [area under the receiving operator characteristic curve (AUROC)=0.942, 0.771 and 0.818, respectively, with P=.047, 0.048 and 0.006, respectively]; ADC values of DW-MRI, however, did not (AUROC=0.797, 0.648 and 0.491, respectively, with P=.100, 0.313 and 0.938, respectively). Reliability of ADC values between right and left hepatic lobes (rho=0.868 and rho=0.910 in the first and second measures of Observer A; rho=0.865 and rho=0.831 in the first and second measures of Observer B) was high and the intra- and interobserver reliability (rho=0.958 in observer A and rho=0.977 in observer B; rho=0.929 in the first measure and rho=0.978 in the second measure between the two observers) were high. All reliability was significant (P<.001). Our results suggest that DW-MRI on a 3-T MRI system is not suitable for predicting postoperative hepatic insufficiency, advanced liver fibrosis, and cirrhosis in patients with HBV-related HCC, despite significantly high reliability.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Area Under Curve
  • Carcinoma, Hepatocellular / complications
  • Carcinoma, Hepatocellular / surgery*
  • Carcinoma, Hepatocellular / virology
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • Hepatic Insufficiency / diagnosis*
  • Hepatitis B / complications*
  • Humans
  • Hyperbilirubinemia / complications
  • Hyperbilirubinemia / diagnosis
  • Liver / pathology
  • Liver / surgery
  • Liver Cirrhosis / complications
  • Liver Cirrhosis / diagnosis
  • Liver Neoplasms / complications
  • Liver Neoplasms / surgery*
  • Liver Neoplasms / virology
  • Male
  • Middle Aged
  • Observer Variation
  • Pilot Projects
  • Postoperative Complications / diagnosis*
  • Predictive Value of Tests
  • Preoperative Care / methods*
  • Prospective Studies
  • ROC Curve
  • Reproducibility of Results
  • Survival Analysis