Influence of calcium hydroxide association on the physical properties of AH Plus

J Endod. 2010 Jun;36(6):1048-51. doi: 10.1016/j.joen.2010.02.007. Epub 2010 Mar 19.

Abstract

Introduction: This study evaluated in vitro the radiopacity, setting time, flow, film thickness, solubility, and dimensional changes of AH Plus sealer pure (Dentsply De Trey Gmbh, Konstanz, Germany) and containing 5% and 10% of calcium hydroxide.

Methods: The study was performed according to the requirements of the ISO 6876:2001 standard and the American National Standards Institute/American Dental Association (ANSI/ADA)'s Specification No. 57. The following tests were performed: setting time, flow, film thickness, dimensional stability, radiopacity, and solubility. Data were analyzed statistically by analysis of variance and the Tukey tests with a significance level of 5%.

Results: The addition of 5% or 10% calcium hydroxide to AH Plus sealer did not alter significantly the radiopacity or setting time values (p > 0.05). Adding 10% calcium hydroxide reduced the flow compared with pure AH Plus and AH Plus/5% calcium hydroxide. The addition of 5% and 10% calcium hydroxide increased the solubility and expansion of AH Plus. All materials presented expansion valued above those recommended by the ADA. The addition of calcium hydroxide to the sealer resulted in greater film thickness.

Conclusions: The addition of 5% calcium hydroxide did not affect most physical properties of AH Plus sealer.

Publication types

  • Comparative Study

MeSH terms

  • Calcium Hydroxide / chemistry*
  • Chemical Phenomena
  • Contrast Media / chemistry
  • Epoxy Resins / chemistry*
  • Hardness
  • Humans
  • Materials Testing
  • Phase Transition
  • Rheology
  • Root Canal Filling Materials / chemistry*
  • Solubility
  • Surface Properties
  • Time Factors
  • Viscosity

Substances

  • Contrast Media
  • Epoxy Resins
  • Root Canal Filling Materials
  • epoxy resin-based root canal sealer
  • Calcium Hydroxide