Background: There remains no reliable non-invasive method to detect cardiac transplant rejection. Recently, speckle-tracking 2-dimensional strain echocardiography (2DSE) was shown to be sensitive in the early detection of myocardial dysfunction in various models of cardiomyopathy. We aim to determine if 2DSE-derived functional indices can detect cardiac transplant rejection.
Methods: Heterotopic rat cardiac transplantation was performed in histocompatible isografts or histoincompatible allografts. Histologic rejection scores were determined. Short-axis, mid-left ventricular (LV) echocardiography was performed on Day 6 after transplantation. Conventional measures of function were measured, (including LV fractional shortening and ejection fraction) as well as 2DSE parameters.
Results: Despite class IIIB rejection in allografts and no rejection in isografts, there was no difference between isografts vs allografts in fractional shortening (15% +/- 3% vs 12% +/- 3%) or ejection fraction (36% +/- 5% vs 26% +/- 6%; both not significant). In contrast, 2DSE revealed decreases between isografts and allografts in global radial strain (12.6% +/- 5.6% vs 1.1% +/- 0.2%, p < 0.05), peak radial systolic strain rate (3.10 +/- 0.74/s vs 0.54 +/- 0.13/s, p < 0.001), and peak circumferential systolic strain rate (-1.99 +/- 0.55 vs -0.43 +/- 0.11/s; p < 0.01).
Conclusions: Systolic strain imaging using 2DSE differentiates myocardial function between experimental cardiac transplant rejection in allografts and non-rejection in isografts. Therefore, 2DSE may be useful in early non-invasive detection of transplant rejection.