In vitro gamma interferon release assays (IGRAs) are increasingly used as an alternative to the traditional tuberculin skin test for the diagnosis of latent Mycobacterium tuberculosis infection. Evaluation of the QuantiFERON-TB Gold in-tube assay (QFT-IT) prior to large-scale implementation at the Stanford Hospital and Clinics for a health care worker screening program revealed a critical preanalytical factor affecting the results. We found that incubation delay significantly increased the frequency of indeterminate results. In this study, QFT-IT was performed with samples from healthy volunteers, and replicate tubes were incubated at 37 degrees C either immediately or after a delay at room temperature for 6 and 12 h. No indeterminate results (0/41) were seen when the assay was performed with immediate incubation. Incubation delays of 6 and 12 h yielded indeterminate results at rates of 10% (2/20) (P = 0.10) and 17.1% (7/41) (P = 0.01), respectively. The increased rate of indeterminate results was due to a decrease in the mean values for the mitogen-nil tubes when incubation was delayed for 6 h (P = 0.004) and 12 h (P < 0.001). The rates of concordance of positive or negative results obtained following immediate incubation and following 6- and 12-h delays were 77.8% (14/18) and 79.4% (27/34), respectively. Subsequent implementation of the immediate incubation procedure in our screening program for 14,830 health care workers yielded an indeterminate result rate of 0.36% over a period of 12 months, a significant improvement over the reported rates of 5 to 40% for QFT-IT. We conclude that immediate incubation of QFT-IT tubes is an effective way to minimize indeterminate results. The effect of incubation delay on the accuracy of QFT-IT remains to be determined.