Transseptal puncture using minimally invasive echocardiography during atrial fibrillation ablation

Europace. 2010 Oct;12(10):1435-8. doi: 10.1093/europace/euq297. Epub 2010 Aug 7.

Abstract

Aims: To assess the usefulness of miniature transoesophageal echocardiography using a 10 F intracardiac probe (ICE-TEE) for transseptal catheterization during atrial fibrillation (AF) ablation.

Methods and results: Intracardiac echocardiography probe was used transoesophageally in 79 consecutive patients (56 ± 11 years, 73% male) referred for AF ablation (60% paroxysmal and 38% persistent) to guide transseptal puncture. Transseptal catheterization monitored by ICE-TEE was well tolerated and successfully performed in all patients without any sedation. No mechanical oesophageal complication was noted. Moreover, the mean duration between ICE-TEE probe insertion and successful transseptal puncture was 4.5 min and the mean time of ICE-TEE was 10 min. Finally, no tamponade occurred during the AF ablation procedure.

Conclusion: Intracardiac echocardiography-TEE is safe and well tolerated for the guidance of transseptal catheterization during AF ablation. Moreover, this technique was performed without requiring any anaesthesia.

Publication types

  • Evaluation Study

MeSH terms

  • Adult
  • Aged
  • Atrial Fibrillation / surgery*
  • Catheter Ablation / adverse effects
  • Catheter Ablation / instrumentation
  • Catheter Ablation / methods*
  • Echocardiography, Transesophageal*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Minimally Invasive Surgical Procedures / adverse effects
  • Minimally Invasive Surgical Procedures / instrumentation
  • Minimally Invasive Surgical Procedures / methods*
  • Prospective Studies
  • Punctures / instrumentation*
  • Treatment Outcome