Abstract

Purpose: The purposes of this study are (1) to develop an efficient aerosol inhalation system for the delivery of [(99m)Tc]DTPA aerosol into guinea pig airways with high uniformity for measuring lung clearance using SPECT/CT imaging, as a measure of lung permeability, and (2) to use [(99m)Tc]DTPA studies in guinea pig model of chronic obstructive pulmonary disease (COPD) to determine its usefulness in studying pathogenesis of COPD.

Procedure: We developed an aerosol delivery system and single-photon emission computed tomography (SPECT) imaging method to measure the pulmonary clearance rate in anesthetized guinea pigs. In this system, an 830-cc rebreather exposure chamber was filled with oxygen immediately before a 5 min [(99m)Tc]DTPA (4-5 mCi/mL) aerosol exposure. The rebreather included a top mounted AeroNeb micro pump nebulizer, a nose-only exposure tube, and rear evacuation port. An 830-cc rebreather exposure chamber was filled with oxygen immediately before 5 min [(99m)Tc]DTPA (4 ∼ 5 mCi/mL) aerosol exposure. One control and one cigarette smoking group were studied.

Results: Images showed high and uniform lung deposition and the mean clearance rate was increased by 37% in smoking group.

Conclusions: The combined SPECT/CT imaging method developed here can be used for serial evaluation of lung function and its response to drug therapy in guinea pig model of COPD.

MeSH terms

  • Animals
  • Disease Models, Animal
  • Guinea Pigs
  • Lung / metabolism*
  • Pulmonary Disease, Chronic Obstructive / diagnosis*
  • Pulmonary Disease, Chronic Obstructive / diagnostic imaging
  • Pulmonary Disease, Chronic Obstructive / metabolism
  • Technetium Tc 99m Pentetate*
  • Tomography, Emission-Computed, Single-Photon / methods*
  • Tomography, X-Ray Computed / methods*

Substances

  • Technetium Tc 99m Pentetate