Use of abdominal chimney grafts is feasible and safe: short-term results

J Endovasc Ther. 2010 Oct;17(5):589-93. doi: 10.1583/10-3083.1.

Abstract

Purpose: To present our initial experience with the use of chimney grafts in endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAAs) with challenging anatomy.

Methods: Among 390 EVAR cases performed at our institution between November 2008 and February 2010, 15 patients (all men; mean age 81.8 years) underwent EVAR with synchronous placement of chimney grafts. The chimney technique involved placing covered stents parallel to the main aortic stent-graft to preserve or rescue flow to aortic branch vessels while extending the proximal fixation zone. All patients presented with pararenal aortic aneurysms with short necks (between 0 and 10 mm long) that required either suprarenal clamping to tailor a proximal anastomosis in open repair or suprarenal fixation to anchor an endoprosthesis. Chimney grafts were implanted into 10 left renal and 5 right renal arteries.

Results: The immediate technical success was 100%. One early type II endoleak due to retrograde flow from the inferior mesenteric artery was detected and is under surveillance. Mean follow-up was 6.8 months (range 1-13). One chimney graft occluded 45 days postoperatively; the patient underwent open thrombectomy of the left renal artery and iliorenal bypass. The creatinine value at discharge was 1.6 mg/dL, and resting renal scintigraphy showed 36% perfusion for the left kidney and 64% for the right kidney. During follow-up, no patient required hemodialysis; no aneurysm-related deaths were noted.

Conclusion: This limited experience demonstrates that the use of abdominal chimney grafts is feasible and safe. Long-term results in larger patient cohorts are needed evaluate the utility of this alternative endovascular technique.

MeSH terms

  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Endoleak / etiology
  • Endoleak / surgery
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Feasibility Studies
  • Germany
  • Graft Occlusion, Vascular / etiology
  • Graft Occlusion, Vascular / surgery
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Prosthesis Design
  • Reoperation
  • Stents*
  • Thrombectomy
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome