Background: The intra-aortic balloon pump (IABP) is used worldwide as an anti-ischemic strategy and to reduce myocardial workload. However, whether IABP augments coronary flow after coronary bypass via a passive increase in diastolic pressure or an active response of the coronary bed remains uncertain.
Methods: We analyzed transit-time flow measurements and the contemporary changes in coronary resistances obtained during 1:1 IABP and during its cessation in 144 consecutive patients receiving prophylactic IABP before isolated coronary artery bypass grafting (n=340 graft segments).
Results: Normally functioning grafts showed lower coronary resistances, greater percentage decrease in resistance, and greater increases in average maximum diastolic and mean flow during 1:1 IABP compared with IABP cessation (P<.001). Arterial and sequential saphenous vein grafts showed better flowmetry and greater reductions in coronary resistances compared with single venous grafts. Accordingly, graft flow reserve (defined as mean flow during 1:1 IABP/mean flow with IABP off) was recruited (graft flow reserve >1) during 1:1 IABP in all normally functioning grafts, with higher values in single arterial or sequential saphenous vein grafts than in single venous grafts (both P<.001). Coronary resistances were higher in 7 failed grafts versus normal-functioning grafts at baseline; these did not decrease during 1:1 IABP and showed worse transit-time flow results.
Conclusions: IABP recruits graft flow reserve by lowering coronary resistance in functioning grafts. Arterial and sequential venous grafts showed greater reduction in coronary resistance compared with single saphenous grafts.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.