Morphological and functional 3-Tesla magnetic resonance imaging of saphenous vein coronary artery bypass grafts

Interact Cardiovasc Thorac Surg. 2011 Apr;12(4):582-5. doi: 10.1510/icvts.2010.255026. Epub 2011 Jan 18.

Abstract

Evaluation of a novel non-invasive tool for postoperative follow-up of patients postelective saphenous vein coronary artery bypass graft (CABG) was performed. Ten patients were included. Their bypass grafts supplied the right coronary artery (7), marginal branches (1), diagonal branches (2), and the circumflex artery (n=1). Each bypass was examined intraoperatively using Doppler flow measurement. Patients were examined with a 3-Tesla magnetic resonance imaging (MRI) scanner (MAGNETOM Verio, Siemens, Erlangen, Germany) within one week postsurgery using MR-angiography with an intravasal contrast agent and velocity encoded phase-contrast flow measurements. Intraoperative Doppler flow measurements revealed regular flow patterns in all vascular territories supplied. The median intraoperative flow rate was 50 ml/min with an inter-quartile range (IQR) of 42-70 ml/min. The clinical postoperative course was uneventful. MRI showed all grafts to be patent. The median postoperative flow rate was 50 ml/min (IQR: 32-65 ml/min). MRI flow rates agreed well with intraoperative Doppler flow measurements (mean difference: -2.8±20.1 ml/min). This initial study demonstrates that 3-Tesla MRI flow measurements correlated well with Doppler thus reconfirming the graft patency postCABG. Further refinement and broader application of this technique may facilitate follow-up postCABG potentially replacing empiric clinical judgment by reliable non-invasive imaging.

Publication types

  • Evaluation Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Blood Flow Velocity
  • Contrast Media
  • Coronary Artery Bypass* / adverse effects
  • Coronary Circulation
  • Elective Surgical Procedures
  • Feasibility Studies
  • Gadolinium
  • Graft Occlusion, Vascular / diagnosis*
  • Graft Occlusion, Vascular / physiopathology
  • Humans
  • Laser-Doppler Flowmetry
  • Magnetic Resonance Angiography*
  • Male
  • Middle Aged
  • Organometallic Compounds
  • Pilot Projects
  • Predictive Value of Tests
  • Saphenous Vein / diagnostic imaging
  • Saphenous Vein / pathology
  • Saphenous Vein / physiopathology
  • Saphenous Vein / transplantation*
  • Switzerland
  • Time Factors
  • Treatment Outcome
  • Ultrasonography
  • Vascular Patency

Substances

  • Contrast Media
  • Organometallic Compounds
  • Gadolinium
  • gadofosveset trisodium